Typical Applications
Model No | PB-LW-05 |
---|---|
Voltage Range |
10.0V min.; 14.8V nom.; 16.8V max. |
Nominal Capacity |
7.2 Ah @ 500mA @ 23°C (74°F) |
Maximum Discharge |
4.0 A continuous @ 23°C (74°F) |
Max. Pulse Discharge |
6.0 A for 5 seconds @ 23°C (74°F) |
Energy | 106 Wh |
Energy Density | 130 Wh/kg, 179 Wh/l |
Weight | 818 grams (1.8 lbs.) |
Cycle Life | > 300 cycles @ C/5 to 80% of initial capacity @ 100% depth of discharge |
Operating Temperature | -20° C to +60° C (-4°F to +140°F) |
Storage Temperature | -20° C to +50° C (-4°F to +122°F) |
Self-Discharge | < 3% per month @ 25°C (77°F) |
Housing | Hard plastic, lusterless, black, UL 94 V-0, NORYL |
Mating Connector | Glenair 8070-1000-07Z16-7SN (Stainless Steel) |
Communications |
|
Contacts | Copper alloy with gold plating over nickel plating |
State of Charge Indicator | 5-Segment LCD Display |
Safety | See Safety Data Sheet – SDS011 |
Transportation | See Safety Data Sheet – SDS011 |
Harmonized Tariff Code | 8507.60.0020 |
Battery Charging | Charge at constant voltage of 16.8 Volts in a temperature range of 0°C to +45°C (+32°F to +113°F), limiting current to 3.0 A max, at 23°C, until current declines to 200 mA. |
Charging Method | The battery should be charged using a constant current/constant voltage (CC/CV) charging method. |