You are here

PB-LWH-01, 11.6Ah, 171Wh, Land Warrior Battery, NSN/MCN: 6140-01-T00-2677, High Capacity, Low Operating Temperature

Rechargeable Lithium-Ion Battery

14.8V, 11.6Ah, 171Wh
PB-LWH-01 Land Warrior Battery - High Capacity

Typical Applications

  • Military Training Systems
  • Back-up Server Power
  • Rugged, Portable Electronics

Standards Compliance

  • CECOM Safety Assessment Approved
  • SMBus v 1.1 smart battery technology compliant
  • SBD v 1.1 smart battery dataset compliant
  • MIL-STD-810G compliant
  • MIL-STD-461F (EMI) compliant
  • UN/DOT Transportation 38.3 T1-T8 compliant
  • Manufactured under ISO 9001:2008 certified quality system

Key Features

  • Charging, discharging and SMBus capabilities available via the connector or flat contacts
  • High Capacity (20% increase vs. PB-LW-01)
  • Low operating temperature (-30°C / -22°F)
  • 5-segment State-of-Charge (SOC) display
  • High energy density
Model No PB-LWH-01
NSN 6140-01-T00-2677
Voltage Range
10.0V min.; 14.8V nom.; 16.8V max.
Nominal Capacity
11.6 Ah @ 500mA @ 23°C (74°F)
Maximum Discharge
5.0 A continuous @ 23°C (74°F)
Max. Pulse Discharge

7.5 A for 5 seconds @ 23°C (74°F)

Energy 171 Wh
Energy Density 171 Wh/kg, 269 Wh/l
Weight > 300 cycles @ C/5 to 80% of initial capacity @ 100% depth of discharge
Cycle Life 998 grams (2.2 lbs.)
Operating Temperature -30° C to +60° C (-22°F to +140°F)
Storage Temperature -20° C to +50° C (-4°F to +122°F)
Self-Discharge < 3% per month @ 25°C (77°F)
Housing Hard plastic, black, lusterless, UL 94 V-0, NORYL
Mating Connector LEMO HEN.1F.305.XLNP
Communications
  • SMBus v1.1 communication protocol
  • SBD v1.1 data set support
Contacts Copper alloy with gold plating over nickel plating
State of Charge Indicator 5-Segment LCD Display
Safety See Safety Data Sheet – SDS055
Transportation See Safety Data Sheet – SDS055
Harmonized Tariff Code 8507.60.0020
Battery Charging Charge at constant voltage of 16.8 Volts in a temperature range of 0°C to +45°C, (+32°F to +113°F), limiting current to 3.0 A max, at 23°C, until current declines to 200 mA.
Charging Method The battery should be charged using a constant current/constant voltage (CC/CV) charging method.
PB-LWH-01 Land Warrior Battery - High Capacity Drawing
  • PC-6010-02  1-bay tactical portable smart charger
  • PC-6805  8-bay tactical portable smart charger
  • PC-3200M/C  32-station bulk smart charger